National Marker Products

Products by Category

DrägerSensor® Smart Ex-IR Drager P/N 6810460, By Draeger

DrägerSensor® Smart Ex-IR Drager P/N 6810460, By Draeger
Catalog #: Drager-Sensor-6810460-Draeger
Our Price: $1,131.45
Quantity in Basket: None
Quantity:

DrägerSensor® Smart Ex-IR Drager P/N 6810460, By Draeger

Gases qualified to measure: Methane, Butane, Cyclohexane, Cyclopentane, Diethyl Ether, Ethane, Ethyl Alcohol, Gasoline, Heptane, Hexane, Methyl Alcohol, Natural Gas, Nonane, Octane, Pentane, Propane, and Propyl Alcohol. Detection of other gases and vapors possible, contact Draeger Safety for details.

Compatible Instruments: X-am 7000 Monitors

Measuring Ranges: 0 to 10000 PPM 0 to 100 %LEL

Response Time: Pump operation: 90% response to exposed concentration in less than 30 seconds

Diffusion operation: 90% response to exposed concentration in less than 40 seconds

Accuracy: Varies with substance measured - +/- 5 % of measured value methane, +/- 4 % of measured value propane

Lowest Display Resolution: 100 PPM for the measuring range of 0 to 10000 PPM, 1 % LEL for the measuring range of 0 to 100 % LEL

Environmental Conditions: Temperature: -13 to 140 °F (-25 to 60 °C), continuous operation

Humidity: 10 to 95 %RH, continuous operation

Pressure: 20.7 to 38.4 inches Hg (700 to 1300 hPa)

Cross-Sensitivities: The sensor will react with many readily oxidized hydrocarbons. The amount of response varies depending substance, contact Draeger Safety for details.

Effects of Poisons: No know substances have a permanent and detrimental effect on the sensor

Calibration Frequency: Recommended: 6 months

Calibration Gas: Required: Match to specific application or contact Draeger for information

Concentration: 40-100% of selected range

Warranty Period: 5 Years

The information contained within this publication is Copyright © 1976 - to present, either by the individual manufacturers, The Safety Equipment Store®, or both parties. The Safety Equipment Store®, and, Your One Source For Workplace Safety®, are Registered Service Marks of S&E Industrial Supply Co., Inc. 1976 - to present.