Google Leads Image
Home     Account     Cart
Find "Products By Category" below left and center, or enter Part Number or Keywords in "Enter Keywords" box above right.

Draeger 6525980, Aerotest, Simultan HP, USA Compliant, with: Deluxe Case, Pressure Reducer, Sampling Manifold, CGA 347 Adapters, Opener, Timer, Instructions, 4 Tube Measuring Device, without  Tubes & Oil Impactor & Adapter.

Dräger 6525980, Aerotest, Simultan HP Kit, USA Compliant, without Tubes or Impactor
    Catalog # Draeger-6525980
    Our Price

    $4,608.33

    List Price $5,120.37

    Description

    Draeger 6525980, Dräger Aerotest® Simultan HP, USA Compliant, Connection: G 5/8, CGA347-I and 825-14 NGO-RH-EXT, without Tubes or Oil Impactor, otherwise complete.

    Dräger Aerotest® Simultan HP is used to determine the quality of respiratory air in high-pressure applications. Quantitative measurements for CO, CO2, H2O and condensed oil / lubricants in breathing apparatus cylinders and compressors are accomplished in minutes.

    Draeger 6525980 High Pressure <4500 psi Aerotest Simultan Kit without Tubes or Oil Impactor, includes:

    • High Pressure Reducer
    • Sampling Manifold for 4 Draeger-tubes
    • CGA 347 Adapter, G5/81 Adapter
    • Deluxe Tube Opener Dräger TO 7000
    • Timer
    • Measuring Device for 4 Dräger-Tubes
    • Without 4 boxes Dräger-Tubes®, Carbon dioxide 100/a-P (10 pcs.) 100 – 3000 ppm 6728521, Carbon monoxide 5/a-P (10 pcs.) 5 – 150 ppm 6728511, Water vapor 20/a-P (10 pcs.) 20-1,500 mg/m3 8103061
    • Without Oil Impactor (10 pcs.) 0.1 – 1 mg/m3 8103560
    • Bubble test hose
    • Impactor Adapter
    • Instruction for use
    • Deluxe Carrying Case

    Dräger Aerotest® Simultan HP/USA, Part Number 6525980

    Connection: G 5/8, CGA347-I and 825-14 NGO-RH-EXT, Comprised of the following components: one high pressure reducer, CGA-347 adapter, G5/81 adapter, measuring device for 4 Dräger-Tubes, impactor adapter, stopwatch, tube opener Dräger TO 7000, bubble test hose, instruction for use, transport case, without Dräger-Tubes®, without Dräger Oil Impactor

    Benefits of the Dräger Aerotest® Simultan HP

    Monitored breathing air

    By using the Dräger Aerotest Simultan HP, the quality of the breathing air from a compressor or a compressed air cylinder can be tested. The application of the test system ensures the reliable testing in accordance with the purification standard EN 12 021. The Aerotest product family is based on the well known Dräger-Tubes – a reliable and quick test method to detect and measure possible toxic gases. The Dräger Aerotest Simultan HP enables the quantitative detection of various potentially harmful substances, e.g. carbon monoxide, carbon dioxide, water vapor and oil in dispersing compressed air. The values can either be determined individually or simultaneously.

    The Dräger Oil Impactor

    The Dräger Oil Impactor is especially designed to detect oil aerosols in compressed air. It is a system that, besides measurements of normal oils, enables the measurement of synthetic oils independent of the oil type and viscosity. Quantitative results are easily visible via a tiered structure.

    Fast and simple application

    Using normal tools, the measuring instrument can be connected to the high-pressure air network. After only a few minutes, the Aerotest displays an indication about the degree of contamination of the filled breathing air.

    Always ready for use

    All components of the Dräger Aerotest Simultan HP are arranged in a transport case and therefore always ready for use.

    Technical Data

    Dräger Aerotest® Simultan HP

    Dimensions (L x W x H) 390 x 315 x 110 mm (15.4 x 12.4 x 4.3 in)
    Weight approx. 3,5 kg (7.7 lbs)
    Supply Pressure 200 / 300 bar (up to 4500 psi)

    Ordering Information

    Dräger Aerotest® Simultan HP/USA Part Number: 6525990

    Connection: G 5/8, CGA347-I and 825-14 NGO-RH-EXT, complete with Dräger-Tubes® and Dräger Oil Impactor, Comprised of the following components: Deluxe Case, High Pressure Reducer, CGA-347 adapter, G5/81 adapter, measuring device for 4 Dräger-Tubes, impactor adapter, stopwatch, tube opener Dräger TO 7000, bubble test hose, instruction for use, with Dräger-Tubes®, Carbon dioxide 100/a-P (10 pcs.) 100 – 3000 ppm 6728521, Carbon monoxide 5/a-P (10 pcs.) 5 – 150 ppm 6728511, Water vapor 20/a-P (10 pcs.) 20-1,500 mg/m3 8103061, Oil Impactor (10 pcs.) 0.1 – 1 mg/m3 8103560

    Accessories

    Dräger-Tubes®

    Carbon dioxide 100/a-P (10 pcs.) 100 – 3000 ppm 6728521
    Carbon monoxide 5/a-P (10 pcs.) 5 – 150 ppm 6728511
    Water vapor 20/a-P (10 pcs.) 20-1,500 mg/m3 8103061

    Dräger Oil Impactor

    Oil Impactor (10 pcs.) 0.1 – 1 mg/m3 8103560

    Dräger-Tubes® are widely used to measure the quality of compressed breathing air, the purity of medical gases, contaminants in process gases, and impurities in technical gases. The Aerotest Kits facilitate these types of measurements by reducing the pressure of the sample to a level at which the Dräger-Tubes® can accurately operate.

    HAZMAT Item: No

    Minimum Order Quantity: 1

    New: YES

    Quantity per Standard Package: 1

    Type: 6525980, Aerotest Simultan HP, USA (w/o Tubes)

    Unit of Measure: EA

    Related Items

    Videos

    close
    DRAEGER-327 DRAEGER-531 Draeger-Aerotest-Kits-Tubes Draeger-Aerotest-Tubes Draeger-Safety-by-Material-Category Draeger-holding-redirected-pending-deletion Draeger-Promotional-Products-List